If accurate results can not be obtained, the solution should be discarded. Home Astm d Astm d April 21, Author: The ACE control system guarantees that the actual electrolysis current produced and the count rate displayed are always correctly synchronised, regardless of changes to the electrolysis cell resistance. Providing fast, accurate and reproducible determinations of water content in liquids, gases and powders. Summary of Test Method 3. For specific precautionary statements see 8. astm d1533

Uploader: Brajin
Date Added: 1 September 2010
File Size: 39.29 Mb
Operating Systems: Windows NT/2000/XP/2003/2003/7/8/10 MacOS 10/X
Downloads: 84285
Price: Free* [*Free Regsitration Required]





Koehler K Coulometric Karl Fischer Titrator (ASTM D, D, D, E) | Labequip

A number in parentheses indicates the year of last reapproval. NOTE 1—For the best accuracy the solution should not be mixed or shaken after standing.

The completion of the reaction is detected with a platinum sensing electrode. Size px x x x x Designed to be equally suitable for meeting the routine needs of the Quality Control laboratory or the more demanding and varied requirements of research d133.

It is the responsibility of the user of this standard to establish appropriate safety and health practice and determine the applicability of regulatory limitations prior to use.

Astm d1533

If a drifting end point is noted, an alternative solvent system or another titration method is warranted. General Use laboratory apparatus balances, baths, blenders, centrifuges, chart recorders, freezers, fume hoods, furnaces, glassware washers, glove boxes, mixers, moisture testing, ovens, pumps, shakers, vacuum equipment, water purification Remove the sample aliquot from the top phase and inject it immediately into the titration cell. No other units of measurement are included in this standard.

The endpoint is determined amperometrically with a platinum electrode that senses a sharp change in cell resistance when the iodine has reacted with all of the water in the test specimen. Please copy and paste this embed script to where you want to embed Embed Script.

astm d1533

Initially, this solution should be mixed thoroughly and allowed to stand at room temperature for at least three days to achieve xstm equilibration. Request a Free Quote Right Now. This test method requires the use of equipment specifically designed for coulometric titration. We need your help! Syringes may be glass or plastic.

Analysis time and date d1353 out Optional Accessories: Automatically controlled Start delay time: Enter product namemake or model. In a sealed system, recleaning and redrying are not necessary for routine use.

No further reproductions authorized. The degree of saturation of the water-saturated 1-Octanol varies. Home Astm d Astm d April 21, Author: Email Us or call toll-free: A detailed discussion of interfering substances can be found in the treatise on aquametry.

If accurate results can not be obtained, the solution should be discarded. Providing fast, accurate asmt reproducible determinations of water content in liquids, gases and powders.

astm d1533

The test specimen is injected into a titration cell where the iodine consumed by the reaction with water is electrolytically regenerated by anodic oxidation of iodide. Summary of Test Method 3.

Koehler K90365 (AKF5000) Coulometric Karl Fischer Titrator

Please help us to share our asym with your friends. Stirring should be at such a rate that an oil layer will not form on top of the reagent. Patented "ACE" control system End point detection: Last previous edition approved in as D — 00 Type text as it appears:: Excess oil may not mix thoroughly with the solvent system thus preventing the total water content of that test specimen from being measured properly.

We need your help to maintenance this website.